NOVOVENT
BOX FILTER / BOX FILTER EC / BOX FILTER R
Filtered supply/extract boxes with G4–F7 filters (EN 779).
models24
Airflow range960 – 51,556 m³/h
SpecificationØ 180–560 mm; up to 51,556 m³/h; motors up to 11 kW; 24 current models
Models
Filter fan box BOX FILTER 1000 EC
- Airflow
- 960
- Diameter
- 24 mm
- Power
- 1 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 600 EC
- Airflow
- 1,105
- Diameter
- 24 mm
- Power
- 0.11 kW
- Sound pressure level (LpA)
- 70 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 800 EC
- Airflow
- 1,105
- Diameter
- 24 mm
- Power
- 0.338 kW
- Sound pressure level (LpA)
- 70 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 1800 EC
- Airflow
- 2,206
- Diameter
- 24 mm
- Power
- 0.4 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 2800 EC
- Airflow
- 3,114
- Diameter
- 24 mm
- Power
- 0.4 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 3000 EC
- Airflow
- 3,114
- Diameter
- 24 mm
- Power
- 0.4 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 180 1.5 kW
- Airflow
- 3,208
- Diameter
- 180 mm
- Power
- 1.5 kW
- Sound pressure level (LpA)
- 78 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 2000 EC
- Airflow
- 3,518
- Diameter
- 24 mm
- Power
- 0.4 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 200 2.2 kW
- Airflow
- 4,313
- Diameter
- 200 mm
- Power
- 2.2 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER A 0.75 kW
- Airflow
- 4,538
- Diameter
- 7 mm
- Power
- 0.75 kW
- Sound pressure level (LpA)
- 62 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER 3500 EC
- Airflow
- 4,586
- Diameter
- 24 mm
- Power
- 1 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 225 3 kW
- Airflow
- 5,000
- Diameter
- 225 mm
- Power
- 3 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 250 4 kW
- Airflow
- 9,860
- Diameter
- 250 mm
- Power
- 4 kW
- Sound pressure level (LpA)
- 71 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER B 2.2 kW
- Airflow
- 10,900
- Diameter
- 10 mm
- Power
- 2.2 kW
- Sound pressure level (LpA)
- 72 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 280 5.5 kW
- Airflow
- 13,489
- Diameter
- 280 mm
- Power
- 5.5 kW
- Sound pressure level (LpA)
- 73 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER C 3 kW
- Airflow
- 14,357
- Diameter
- 12 mm
- Power
- 3 kW
- Sound pressure level (LpA)
- 70 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 315 5.5 kW
- Airflow
- 15,743
- Diameter
- 315 mm
- Power
- 5.5 kW
- Sound pressure level (LpA)
- 82 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER D 5.5 kW
- Airflow
- 18,134
- Diameter
- 15 mm
- Power
- 5.5 kW
- Sound pressure level (LpA)
- 68 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 400 7.5 kW
- Airflow
- 24,572
- Diameter
- 400 mm
- Power
- 7.5 kW
- Sound pressure level (LpA)
- 73 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 355 7.5 kW
- Airflow
- 26,638
- Diameter
- 355 mm
- Power
- 7.5 kW
- Sound pressure level (LpA)
- 78 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 450 11 kW
- Airflow
- 31,923
- Diameter
- 450 mm
- Power
- 11 kW
- Sound pressure level (LpA)
- 71 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER E 7.5 kW
- Airflow
- 32,782
- Diameter
- 18 mm
- Power
- 7.5 kW
- Sound pressure level (LpA)
- 73 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 500 11 kW
- Airflow
- 38,635
- Diameter
- 500 mm
- Power
- 11 kW
- Sound pressure level (LpA)
- 69 dB(A)
- Fire rating
- —
Filter fan box BOX FILTER R 560 11 kW
- Airflow
- 51,556
- Diameter
- 560 mm
- Power
- 11 kW
- Sound pressure level (LpA)
- 71 dB(A)
- Fire rating
- —
Series applications
Hospitals & HealthcareOffices & BanksUniversities & Schools
Performance curves
Performance curves
Original BOX FILTER / BOX FILTER EC / BOX FILTER R catalogue chart pages; match the model, speed and configuration.
Data per the official NOVOVENT catalogue. Maximum free-air values; final selection at the duty point is confirmed by an IMETCO engineer.