NOVOVENT
ECS / ECS EC / IN NOVO / IN NOVO EC
In-line mixed-flow duct fans; EC versions with 0–10 V control.
models70
Airflow range14 – 1,035 m³/h
SpecificationØ 100–200 mm; up to 1,035 m³/h; motors up to 0.115 kW; 70 current models
Models
Ceiling and duct extract fan IN-NOVO 100 4.9
- Airflow
- 14
- Diameter
- 12 mm
- Power
- —
- Sound pressure level (LpA)
- —
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 125 4.9
- Airflow
- 14
- Diameter
- 12 mm
- Power
- —
- Sound pressure level (LpA)
- —
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 150 13.9
- Airflow
- 23
- Diameter
- 21 mm
- Power
- —
- Sound pressure level (LpA)
- —
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 160 13.9
- Airflow
- 23
- Diameter
- 21 mm
- Power
- —
- Sound pressure level (LpA)
- —
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 200 13.9
- Airflow
- 23
- Diameter
- 21 mm
- Power
- —
- Sound pressure level (LpA)
- —
- Fire rating
- —
Ceiling and duct extract fan ECS 100
- Airflow
- 174
- Diameter
- 100 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 28 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 100
- Airflow
- 174
- Diameter
- 100 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 28 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 125 EC
- Airflow
- 180
- Diameter
- 125 mm
- Power
- 0.012 kW
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 125 EC
- Airflow
- 180
- Diameter
- 125 mm
- Power
- 0.012 kW
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 100
- Airflow
- 180
- Diameter
- 100 mm
- Power
- —
- Sound pressure level (LpA)
- 28 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 100 EC
- Airflow
- 180
- Diameter
- 100 mm
- Power
- —
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 100T
- Airflow
- 180
- Diameter
- 100 mm
- Power
- —
- Sound pressure level (LpA)
- 28 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 100 EC
- Airflow
- 181
- Diameter
- 100 mm
- Power
- 0.009 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 100 EC
- Airflow
- 181
- Diameter
- 100 mm
- Power
- 0.009 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 125
- Airflow
- 190
- Diameter
- 125 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 30 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 125
- Airflow
- 190
- Diameter
- 125 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 30 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 125 EC
- Airflow
- 190
- Diameter
- 125 mm
- Power
- —
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 125
- Airflow
- 200
- Diameter
- 125 mm
- Power
- —
- Sound pressure level (LpA)
- 29 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 125T
- Airflow
- 200
- Diameter
- 125 mm
- Power
- —
- Sound pressure level (LpA)
- 29 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 100 EC PLUS
- Airflow
- 257
- Diameter
- 100 mm
- Power
- 0.012 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 100 EC PLUS
- Airflow
- 257
- Diameter
- 100 mm
- Power
- 0.012 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 100 EC PLUS
- Airflow
- 260
- Diameter
- 100 mm
- Power
- —
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 125 EC PLUS
- Airflow
- 298
- Diameter
- 125 mm
- Power
- 0.012 kW
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 125 EC PLUS
- Airflow
- 298
- Diameter
- 125 mm
- Power
- 0.012 kW
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 100 PLUS
- Airflow
- 300
- Diameter
- 100 mm
- Power
- 0.082 kW
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 100 PLUS
- Airflow
- 300
- Diameter
- 100 mm
- Power
- 0.082 kW
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 125 EC PLUS
- Airflow
- 300
- Diameter
- 125 mm
- Power
- —
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 100T PLUS
- Airflow
- 300
- Diameter
- 100 mm
- Power
- —
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 150 EC
- Airflow
- 308
- Diameter
- 150 mm
- Power
- 0.022 kW
- Sound pressure level (LpA)
- 33 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 150 EC
- Airflow
- 308
- Diameter
- 150 mm
- Power
- 0.022 kW
- Sound pressure level (LpA)
- 33 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 160 EC
- Airflow
- 308
- Diameter
- 160 mm
- Power
- 0.023 kW
- Sound pressure level (LpA)
- 33 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 150 EC
- Airflow
- 310
- Diameter
- 150 mm
- Power
- —
- Sound pressure level (LpA)
- 33 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 125T PLUS
- Airflow
- 370
- Diameter
- 125 mm
- Power
- —
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 125 PLUS
- Airflow
- 371
- Diameter
- 125 mm
- Power
- 0.082 kW
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 125 PLUS
- Airflow
- 371
- Diameter
- 125 mm
- Power
- 0.082 kW
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 150
- Airflow
- 386
- Diameter
- 150 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 160
- Airflow
- 386
- Diameter
- 160 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 150
- Airflow
- 386
- Diameter
- 150 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 160
- Airflow
- 386
- Diameter
- 160 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 150
- Airflow
- 390
- Diameter
- 150 mm
- Power
- —
- Sound pressure level (LpA)
- 30 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 160
- Airflow
- 390
- Diameter
- 160 mm
- Power
- —
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 150T
- Airflow
- 390
- Diameter
- 150 mm
- Power
- —
- Sound pressure level (LpA)
- 30 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 160T
- Airflow
- 390
- Diameter
- 160 mm
- Power
- —
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 160 EC
- Airflow
- 400
- Diameter
- 160 mm
- Power
- 0.023 kW
- Sound pressure level (LpA)
- 33 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 160 EC
- Airflow
- 410
- Diameter
- 160 mm
- Power
- —
- Sound pressure level (LpA)
- 33 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 200
- Airflow
- 490
- Diameter
- 200 mm
- Power
- —
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 200T
- Airflow
- 490
- Diameter
- 200 mm
- Power
- —
- Sound pressure level (LpA)
- 31 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 200
- Airflow
- 494
- Diameter
- 200 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 200
- Airflow
- 494
- Diameter
- 200 mm
- Power
- 0.027 kW
- Sound pressure level (LpA)
- 32 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 200 EC
- Airflow
- 500
- Diameter
- 200 mm
- Power
- —
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 200 EC
- Airflow
- 517
- Diameter
- 200 mm
- Power
- 0.023 kW
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 200 EC
- Airflow
- 517
- Diameter
- 200 mm
- Power
- 0.023 kW
- Sound pressure level (LpA)
- 34 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 150 PLUS
- Airflow
- 781
- Diameter
- 150 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 160 PLUS
- Airflow
- 781
- Diameter
- 160 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 150 PLUS
- Airflow
- 781
- Diameter
- 150 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 160 PLUS
- Airflow
- 781
- Diameter
- 160 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 150 PLUS
- Airflow
- 800
- Diameter
- 150 mm
- Power
- —
- Sound pressure level (LpA)
- 41 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 160 PLUS
- Airflow
- 800
- Diameter
- 160 mm
- Power
- —
- Sound pressure level (LpA)
- 41 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 150 EC PLUS
- Airflow
- 800
- Diameter
- 150 mm
- Power
- —
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 160 EC PLUS
- Airflow
- 800
- Diameter
- 160 mm
- Power
- —
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 150T PLUS
- Airflow
- 800
- Diameter
- 150 mm
- Power
- —
- Sound pressure level (LpA)
- 41 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 160T PLUS
- Airflow
- 800
- Diameter
- 160 mm
- Power
- —
- Sound pressure level (LpA)
- 41 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 150 EC PLUS
- Airflow
- 801
- Diameter
- 150 mm
- Power
- 0.11 kW
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 160 EC PLUS
- Airflow
- 801
- Diameter
- 160 mm
- Power
- 0.11 kW
- Sound pressure level (LpA)
- 40 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 200 PLUS
- Airflow
- 898
- Diameter
- 200 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 42 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN NOVO 200 PLUS
- Airflow
- 898
- Diameter
- 200 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 42 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 200 PLUS
- Airflow
- 900
- Diameter
- 200 mm
- Power
- —
- Sound pressure level (LpA)
- 42 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 200T PLUS
- Airflow
- 900
- Diameter
- 200 mm
- Power
- —
- Sound pressure level (LpA)
- 42 dB(A)
- Fire rating
- —
Ceiling and duct extract fan IN-NOVO 200 EC PLUS
- Airflow
- 1,030
- Diameter
- 200 mm
- Power
- —
- Sound pressure level (LpA)
- 41 dB(A)
- Fire rating
- —
Ceiling and duct extract fan ECS 200 EC PLUS
- Airflow
- 1,035
- Diameter
- 200 mm
- Power
- 0.115 kW
- Sound pressure level (LpA)
- 41 dB(A)
- Fire rating
- —
Series applications
Offices & BanksHotels & MallsResidential
Performance curves
Performance curves
Original ECS / ECS EC / IN NOVO / IN NOVO EC catalogue chart pages; match the model, speed and configuration.
Data per the official NOVOVENT catalogue. Maximum free-air values; final selection at the duty point is confirmed by an IMETCO engineer.